1003h Pre-defined error field
The object 1003h provides an error history with a maximum size of 10 entries.
Sub-index 0 contains the number of errors that have occurred since startup of the drive or since the last reset. The error history can be reset by writing 0 to sub-index 0.
When an EMCY message is sent from the drive, the first four bytes of the message is written into sub-index 1. The previous entries are shifted one sub-index higher and the content in the last sub-index is dropped.
For more information about the EMCY message structure, see EMCY Object.
Name | Index | Sub-Index | Data Type | Float Scale | Units | Access | PDO Mappable |
---|---|---|---|---|---|---|---|
Number of errors | 1003h | 0h | Unsigned8 | - | - | Read/Write | No |
Standard error field | 1003h | 1h | Unsigned32 | - | - | Read only | No |
Standard error field | 1003h | 2h | Unsigned32 | - | - | Read only | No |
Standard error field | 1003h | 3h | Unsigned32 | - | - | Read only | No |
Standard error field | 1003h | 4h | Unsigned32 | - | - | Read only | No |
Standard error field | 1003h | 5h | Unsigned32 | - | - | Read only | No |
Standard error field | 1003h | 6h | Unsigned32 | - | - | Read only | No |
Standard error field | 1003h | 7h | Unsigned32 | - | - | Read only | No |
Standard error field | 1003h | 8h | Unsigned32 | - | - | Read only | No |
Standard error field | 1003h | 9h | Unsigned32 | - | - | Read only | No |
Standard error field | 1003h | Ah | Unsigned32 | - | - | Read only | No |